Wiring – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 171

Advertising
background image

2 - 102

37 SIEMENS PLC

6

Available Memory

The assigned memory is indicated while editing the screen as illustrated:

Set the memory to the extent of the memory range of each PLC model.

Use TYPE number to assign indirect memory for macro programs.

Wiring

The following is a diagram to show the wiring of the cable which connects POD to PLC.

RS-232C

Wiring Diagram 1

Wiring Diagram 2

<E.g.> DB0001: 0000

Block No.

Address No.

D-sub 25pin(Male: )

HMI Adapter

PC Adapter

D-sub 9pin(Female: )

*

Use twist shielded cables.

FG

SD

RD

RS

CS

SG

2

1

3

4

5

7

RD

SD

SG

RTS

CTS

6

5

8

1

7

POD (CN1)

Memory

TYPE

Remarks

DB

(data register)

0

Use memories more than DB1.

I

(input relay)

1

IW as word device

Q

(output relay)

2

QW as word device

M

(Merker Word)

3

MW as word device

T

(timer/current value)

4

C

(counter/current value)

5

POD (CN1)

D-sub 25pin(Male: )

FG

+SD

-SD

+RD

PLC

D-sub 9pin(Male: )

+RD/SD

-RD/SD

3

8

-RD

1

12

13

24

25

* Use twist shielded cables.