42 keyence plc . 3, Keyence plc • 3 -112, Keyence plc • 3 – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 181: Kv / kz series), Available plc, Communication setting

Advertising
background image

2 - 112

42

KEYENCE PLC • 3

(KV / KZ series)

42 KEYENCE PLC

3

Wiring Diagram

PLC

KZ-10/16/24/40/80/300/350
(Program port direct connection)

KV Series
(Program port direct connection)

RS-232C [Wiring Diagram 1] or

Cable made by KEYENCE [OP-26487]

+Connector made by KEYENCE [OP-26485]

Select PLC Type

KZ/KV

Series CPU

KZ 24/300

CPU

KZ 10/24

CPU

RS-422

Cable made by KEYENCE [KZ-C20]

+Cable made by FUJI [ UG200C-M ]

KZ-24/300
(Program port direct connection)

KZ-10/24
(Program port direct connection)

RS-232C [Wiring Diagram 1] or

Cable made by KEYENCE [OP-26487]

+Connector made by KEYENCE [OP-26485]

KV 700

CPU

KZ 700
(Program port direct connection)

Even

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

Item

Setting of PLC

0

Port

0

38400bps

8

1

Comm. Parameter of POD

38400bps

*

1

Even

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

Item

Setting of PLC

0

Port

0

57600bps

8

1

Comm. Parameter of POD

57600bps

*

1

Available PLC

*

When using RS232C cable made by KEYENCE [OP-26487] , attach the D-sub 25 pins connecter

[OP-26485] to the modular jack on the POD side to communicate.

Communication Setting

KV series / KV 700 series CPU

The communication parameter setting of POD is done automatically.

KZ24/300 series CPU

*

1 Maximum baud rate is 38400 bps.If 57600bps or 115000bps is selected, POD communicates with a PLC forcibly at 9600 bps.

KV10/24 series CPU

*

1 Maximum baud rate is 38400 bps.If 57600bps or 115000bps is selected, POD communicates with a PLC forcibly at 9600 bps.

KV700 series CPU

*

1 Maximum baud rate is 57600 bps.

Even

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

Item

Setting of PLC

0

Port

0

9600bps

8

1

Comm. Parameter of POD

9600bps

*

1