Wiring – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 162

Advertising
background image

2 - 93

32 SIEMENS PLC

1

*

Notes on converting the data file of UG400 (or UG200) into the UGx20 data file.

When converting the data file of UG400 (or UG200) into the UGx20 data file,

the PLC type is automatically selected as “SIEMENS S5 UG400.”

In UG400 (or UG200) , the order of bytes in I (input relay), Q (output relay) and

F (internal relay) is reversed.

Wiring

The following is a diagram to show the wiring of the cable which connects POD to PLC.

RS-232C

Wiring Diagram 1

Wiring Diagram 2

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

F0000210

F0000217

Memory setting

of UG400 (or UG200)

Memories to be accessed

to PLC by UG400 (or UG200)

F0000200

F0000207

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

F0000210

F0000217

F0000200

F0000207

Memory setting

of UxG20

Memories

to be accessed

to PLC by UGx20

FW20

FW20

Exsample:
S5 UG400

Exsample:
S5, S7

D-sub 25pin(Male: )

FG

SD

RD

RS

CS

TXD

PLC

D-sub 25pin(Male: )

RXD

GND

2

3

7

SG

2

1

3

4

5

7

POD (CN1)

*

Use twist shielded cables.

D-sub 25pin(Male: )

FG

SD

RD

RS

CS

TXD

PLC

D-sub 25pin(Male: )

RXD

2

3

4

SG

2

1

3

4

5

7

GND

5

7

6ES5 734-1BD20

S5-95U

POD (CN1)

*

Use twist shielded cables.

Advertising