How to install ug00p-di, How to use ug00p-di, Precautions for use – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 230: Gd g p p, 6 connecting the dual port interface

Advertising
background image

3 - 16

6 Connecting the Dual Port Interface

How to install UG00P-DI

To connect the UG00P-DI to A series PLC of small type (A1S, A2US, etc.), it is necessary to mount the

bracket that is supplied with the UG00P-DI.

MELSEC Axsxxx

MITSUBISHI

POWER

MELSEC AxS

CPU

RUN

L.CLR

ERROR

RESET

RUN

STOP

RESET

MITSUBISHI

MELSEC Axsxxx

MITSUBISHI

POWER

MELSEC AxS

CPU

RUN

L.CLR

ERROR

RESET

RUN

STOP

RESET

MITSUBISHI

GPP

UG00P-DI

UG

GPP

Not used

Surely tighten
the screws.

Fit the bracket
according to the
figure at right.

Surely tighten the
screw after mounting
the bracket.

50

16.3

6.5

[Dimensions of

the bracket]

(Used to connect to A or
QnA series of large type)

(Unit: mm)

UG00P-DI

UG

1 2 3

1 2 3

GD

G

P

P

UG00P-DI

UG

UG00P-D

I

1 2 3

1 2 3

UG00P-D

I

UG00P-DI

CPU

Personal computer, A6GPP, A7PHP, etc.

POD
UG520/420/320/221/220
UG400/210

When connecting to A series or QnA series CPU,

insert the connector provided on the rear
directly to the CPU port, or use UG200C-G
(sold separately).

When connecting to FX1/2 series CPU, use

UG200C-G (sold separately).

When connecting to FX0N/2N series CPU, use the

conversion cable (FX-20P-CADP) supplied
from Mitsubishi.

Mitsubishi A/QnA/FX series

Connector for GPP
(can be used to connect
POD)

Connector
for POD

Connector for
CPU port

Enlarged view

GPP

Sliding switch
Used to select the model of
connected device.
1. A series (ACPU port)
2. QnA series (QnACPU port)
3. FX series

Note:

Be sure to turn the power off
when changing over of the
sliding switch.

UG200C-M

UG200C-G (sold separately).

How to Use UG00P-DI

1) To use for debugging

Connect to POD or GPP (personal computer, A6GPP, etc.)

2) To use for connecting two units of POD

PODs can be connected on the GPP side as well as on the UG side (see the above figure).

For this, the cable used on the GPP side must be the same as that used on the UG side (UG200C-M).

Precautions for Use

1. Be careful of the capacity of the 5V power supply of the CPU because the UG00P-DI is supplied power

from the CPU (current consumption: max. 350 mA).

2. The wiring length between the CPU and the UG00P-DI shall be as short as possible (max. 1 to 1.5 m).