Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 100

Advertising
background image

5 - 15

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

42

*DI1

0002

Refer to
Name
and
function
column.

P/S

Ex

pan

si

on

par

ame

te

rs

1

Input signal selection 1

Used to assign the control mode changing signal input pins and to set
the clear (CR).

Control change (LOP) input pin
assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/int-
ernal speed change mode.

Set value

0
1

2

Connector pin No.

CN1-4
CN1-3

CN1-5

3

CN1-6

Clear (CR) selection

0: Droop pulses are cleared on the

leading edge.

1: While turning on, droop pulses are
always cleared.

4

CN1-7

0 0

If forward rotation stroke end (LSP)
or reverse rotation stroke end
(LSN) is assigned to any pin with
parameter No. 48, this setting is
invalid.

P S

Advertising