5 - 11

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

20

*OP2

0000

Refer to
Name
and
function
column.

S

P S

Function selection 2

Used to select restart after instantaneous power failure,
servo lock at a stop in internal speed control mode, and slight
vibration suppression control.

0: Invalid
1: Valid

If the input power supply voltage
had reduced in the internal speed
control mode to stop the servo motor
due to the undervoltage alarm (AL.10)
but the supply voltage has return-
ed to normal, the servo motor can
be restarted by merely switching
on the start signal without resett-
ing the alarm.

Restart after instantaneous
power failure

Stop-time servo lock selection

The shaft can be servo-locked to
remain still at a stop in the internal
speed control mode.

0: Valid
1: Invalid

Slight vibration suppression control

Made valid when auto tuning selection is
set to "0400" in parameter No. 2.
Used to suppress vibration at a stop.

0: Invalid
1: Valid

Encoder cable communication system selection

Incorrect setting will result in an encoder alarm 1
(AL. 16) or encoder alarm 2 (AL. 20).

0: Two-wire type
1: Four-wire type

In case of the internal speed control mode,
set "1" at the second digit and validate servo
lock at stop to use this setting.

P S

Ex

pan

si

on

par

ame

te

rs

1

21

*OP3 Function selection 3 (Command pulse selection)

Used to select the input form of the pulse train input signal.
(Refer to Section 3.4.1.)

Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A/B phase pulse train

Pulse train logic selection
0: Positive logic
1: Negative logic

0 0

0000

Refer to
Name
and
function
column.

P