Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 90

Advertising
background image

5 - 5

5. PARAMETERS

(2) Details list

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

Control mode, regenerative brake option selection

Used to select the control mode and regenerative brake option.

Select the control mode.
0:Position
1:Position and internal speed
2:Internal speed

Selection of regenerative brake option
0:Not used
(The built-in regenerative brake resistor used.)
2:MR-RB032
3:MR-RB12
4:MR-RB32
5:MR-RB30
6:MR-RB50

Motor series selection
0:HC-KFE
1:HC-SFE

Motor capacity selection
0:100W
1:200W
2:400W
3:500W
4:750W
5:1kW
6:1.5kW
7:2kW

POINT

Wrong setting may cause the regenerative brake option to burn.

If the regenerative brake option selected is not for use with the
servo amplifier, parameter error (AL.37) occurs.

0

*STY

100W
: 0000

200W
: 1000

400W
: 2000

750W
: 4000

1kW
: 5010

2kW
: 6010

Refer to
Name
and
function
column.

P S

B

asi

c p

ara

m

et

ers

1

*OP1 Function selection 1

Used to select the input signal filter, the function of pin CN1-12.

Input signal filter
If external input signal causes chattering
due to noise, etc., input filter is used to
suppress it.
0:None
1:1.777[ms]
2:3.555[ms]
3:5.333[ms]

CN1-12 function selection
0:Zero Speed detection signal
1:Electromagnetic brake interlock signal

0

0

0002

Refer to
Name
and
function
column.

P S

Advertising