5 - 14

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

35

PG2

Position loop gain 2

Used to set the gain of the position loop.
Set this parameter to increase the position response to level load
disturbance. Higher setting increases the response level but is liable
to generate vibration and/or noise.
When auto tuning mode 1,2 and interpolation mode is selected, the
result of auto tuning is automatically used.

35

rad/s

1

to

1000

P

36

VG1

Speed loop gain 1

Normally this parameter setting need not be changed.
Higher setting increases the response level but is liable to generate
vibration and/or noise.
When auto tuning mode 1 2, manual mode and interpolation mode
is selected, the result of auto tuning is automatically used.

177

rad/s

20

to

8000

P S

37

VG2

Speed loop gain 2

Set this parameter when vibration occurs on machines of low rigidity
or large backlash. Higher setting increases the response level but is
liable to generate vibration and/or noise.
When auto tuning mode 1 2 and interpolation mode is selected, the
result of auto tuning is automatically used.

817

rad/s

20

to

20000

P S

38

VIC

Speed integral compensation

Used to set the integral time constant of the speed loop.
Higher setting increases the response level but is liable to generate
vibration and/or noise.
When auto tuning mode 1 2 and interpolation mode is selected, the
result of auto tuning is automatically used.

48

ms

1

to

1000

P S

39

VDC

Speed differential compensation

Used to set the differential compensation.
Made valid when the proportion control (PC) is switched on.

980

0

to

1000

P S

40

For manufacturer setting
Don’t change this value by any means.

0

Refer to
Name
and
function
column.

P S

Ex

pan

si

on

par

ame

te

rs

1

41

*DIA Input signal automatic ON selection

Used to set automatic servo-on (SON) forward rotation stroke end
(LSP) reverse rotation stroke end (LSN).

Servo-on (SON) input selection

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

Reverse rotation stroke end (LSN)
input selection

Forward rotation stroke end (LSP)
input selection

0

0000

P S