6 servo system with auxiliary equipment, Warning – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 251

Advertising
background image

15 - 6

15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

15.1.6 Servo system with auxiliary equipment

WARNING

To prevent an electric shock, always connect the protective earth (PE) terminal

(terminal marked ) of the servo amplifier to the protective earth (PE) of the control

box.

(1) MR-E-100AG or less

MODE

CN3

SET

CN1

CN2

CNP2

CNP1

L3

L

2

L1

D

C

P

W

V

U

CHARGE

P

C

L

3

L

2

L

1

(Note 2)
3-phase 200V
to 230VAC power
supply or
1-phase 230VAC
power supply

No-fuse breaker
(NFB) or fuse

Magnetic
contactor
(MC)

To CN2

To CN1

To CN3

Protective earth
(PE) terminal

Servo motor

Personal
computer

Servo amplifier

Regenerative option

Options and auxiliary equipment

No-fuse breaker

Magnetic contactor

Servo configuration software

Regenerative option

Refer to

Section 13.2.2
Section 13.2.2
Section 13.1.4

Section 13.1.1

(Note 1)
Encoder cable

Options and auxiliary equipment

Refer to

Cables

Section 13.2.1

Command device

(Note 1)
Power supply lead

Power
factor
improving
reactor
(FR-BAL)

Power factor improving reactor Section 13.2.3

Note: 1. The HC-SFE series have cannon connectors.
2. A 1-phase 230VAC power supply may be used with the servo amplifier of MR-E-70AG or less. Connect the power supply to
L

1

and L

2

terminals and leave L

3

open.

Servo configuration
software
MRZJW3-SETUP1

MITSUBISHI
MR-E-

Advertising