6 - 5

6. DISPLAY AND OPERATION

6.3 Diagnostic mode

Name

Display

Description

Not ready.
Indicates that the servo amplifier is being initialized or an alarm
has occurred.

Sequence

Ready.
Indicates that the servo was switched on after completion of
initialization and the servo amplifier is ready to operate.

External I/O signal
display

Refer to section 6.6.

Indicates the ON-OFF states of the external I/O signals.
The upper segments correspond to the input signals and the
lower segments to the output signals.

Lit: ON
Extinguished: OFF

The I/O signals can be changed using parameters No. 43 to 49.

Output signal (DO)
forced output

The digital output signal can be forced on/off. For more
information, refer to section 6.7.

Jog feed

Jog operation can be performed when there is no command from
the external command device.
For details, refer to section 6.8.2.

Positioning
operation

The servo configuration software (MRZJW3-SETUP154E) is
required for positioning operation. This operation cannot be
performed from the operation section of the servo amplifier.
Positioning operation can be performed once when there is no
command from the external command device.

Motorless
operation

Without connection of the servo motor, the servo amplifier
provides output signals and displays the status as if the servo
motor is running actually in response to the external input
signal.
For details, refer to section 6.8.4.

Test
operation
mode

Machine
analyzer
operation

Merely connecting the servo amplifier allows the resonance point
of the mechanical system to be measured.
The servo configuration software (MRZJW3-SETUP154E or later)
is required for machine analyzer operation.

Software version low

Indicates the version of the software.

Software version high

Indicates the system number of the software.

Manufacturer setting
screen

Screen for manufacturer setting. When this screen is being
displayed, do not press any other buttons than "UP" and "DOWN"
button.

Motor series

Press the "SET" button to show the motor series ID of the servo
motor currently connected.

Motor type

Press the "SET" button to show the motor type ID of the servo
motor currently connected.

Encoder

Press the "SET" button to show the encoder ID of the servo motor
currently connected.