MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 295

Advertising
background image

15 - 50

15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

65

*CDP Gain changing selection

Used to select the gain changing condition. (Refer to Section 8.5.)

0

0 0

Gain changing selection

Gains are changed in accordance with the settings
of parameters No. 61 to 64 under any of the following
conditions:

0: Invalid
1: Gain changing (CDP) is ON
2: For manufacturer setting
3: For manufacturer setting
4: Servo motor speed is equal to higher than
parameter No. 66 setting

0000

Refer to
Name
and
function
column.

S

66

CDS

Gain changing condition

Used to set the value of gain changing condition (command
frequency, droop pulses, servo motor speed) selected in parameter
No. 65.The set value unit changes with the changing condition item.
(Refer to Section 8.5.)

10

kpps

pulse

r/min

10

to

9999

S

67

CDT

Gain changing time constant

Used to set the time constant at which the gains will change in
response to the conditions set in parameters No. 65 and 66.
(Refer to Section 8.5.)

1

ms

0

to

100

S

68

For manufacturer setting
Don’t change this value by any means.

0

69

1

70

1

71

1

Internal speed command 4

Used to set speed 4 of internal speed commands.

S

72

SC4

Internal speed limit 4

Used to set speed 4 of internal speed limits.

200

r/min 0 to in-

stanta-

neous

permi-

ssible
speed

T

Internal speed command 5

Used to set speed 5 of internal speed commands.

S

73

SC5

Internal speed limit 5

Used to set speed 5 of internal speed limits.

300

r/min 0 to in-

stanta-

neous

permi-

ssible
speed

Internal speed command 6

Used to set speed 6 of internal speed commands.

S

74

SC6

Internal speed limit 6

Used to set speed 6 of internal speed limits.

500

r/min 0 to in-

stanta-

neous

permi-

ssible
speed

T

Internal speed command 7

Used to set speed 7 of internal speed commands.

S

Ex

pan

si

on

par

ame

te

rs

2

75

SC7

Internal speed limit 7

Used to set speed 7 of internal speed limits.

800

r/min 0 to in-

stanta-

neous

permi-

ssible
speed

T

Advertising