15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

S

22

*OP4 Function selection 4

Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN) off, choose TLC/VLC output and
choose VC/VLA voltage averaging.

How to make a stop when forward
rotation stroke end (LSP)
reverse rotation stroke end (LSN)
is valid. (Refer to Section 5.2.3.)

0: Sudden stop
1: Slow stop

Set value

0
1

2

Filtering time [ms]

0

0.444

0.888

3

1.777

VC/VLA voltage averaging

Used to set the filtering time when the
analog speed command (VC) voltage
or analog speed limit (VLA) is imported.
Set 0 to vary the speed to voltage fluctua-
tion in real time. Increase the set value
to vary the speed slower to voltage flu-
ctuation.

4

3.555

0

Set value

0
1

2

Connector pin No.

Not output

CN1-11

CN1-9

3

CN1-10

TLC/VLC output selection

Select the connector pin at which
Torque Limit (TLC) or Speed Limit
(VLC) is output.

4

CN1-12

0000

Refer to
Name
and
function
column.

S T

23

For manufacturer setting
Don’t change this value by anymeans.

0

24

ZSP

Zero speed

Used to set the output range of the zero speed (ZSP).

50

r/min

0

to

10000

S T

0

Analog speed command maximum speed

Used to set the speed at the maximum input voltage (10V) of the

analog speed command (VC).

Set "0" to select the rated speed of the servo motor connected.

0

r/min

1

to

50000

S

0

25

VCM

Analog speed limit maximum speed

Used to set the speed at the maximum input voltage (10V) of the

analog speed limit (VLA).

Set "0" to select the rated speed of the servo motor connected.

0

r/min

1

to

50000

T

E

xp

ansi

on

p

ara

m

et

ers

1

26

TLC

Analog torque command maximum output

Used to set the output torque at the analog torque command voltage

(TC 8V) of 8V on the assumption that the maximum torque is

100[%]. For example, set 50 to output (maximum torque 50/100) at

the TC of 8V.

100

%

0

to

1000

T

Advertising