Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 104

Advertising
background image

5 - 19

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

Ex

pan

si

on

par

ame

te

rs

1

49

*DO1 Output signal selection 1

Used to select the connector pins to output the alarm code and
warning (WNG).

Setting of alarm code output

Connector pins

Set value

CN1-10

CN1-11

CN1-12

0

INP or SA

RD

ZSP

1

88888
AL.12
AL.13
AL.15
AL.17

AL.8A
AL.8E

AL.30

AL.45

AL.50
AL.51
AL.24
AL.32
AL.31
AL.35
AL.52
AL.16

AL.20

Name

Watchdog
Memory error 1
Clock error
Memory error 2
Board error 2

Serial communication time-out error

Serial communication error
Regenerative error

Main circuit device overheat

Overload 1
Overload 2
Main circuit
Overcurrent
Overspeed
Command pulse frequency error
Error excessive
Encoder error 1

Encoder error 2

Alarm

display

(Note) Alarm code

CN1

pin 10

0

0

0

0

1

CN1

pin 11

0

0

1

1

0

1

CN1

pin 12

1

1

0

1

0

1

0

Set value

Connector pin No.

Note: 0:off

1:on

Setting of warning (WNG) output

Select the connector pin to output warning. The old signal
before selection will be unavailable.

AL.19 Memory error 3
AL.37 Parameter error

AL.33 Overvoltage

AL.46 Servo motor overheat

AL.10 Undervoltage

1

0

0

AL.1A Motor combination error

0

Not output.

1

CN1-11

2

CN1-9

3

CN1-10

4

CN1-12

0

Alarm code is output at alarm occurrence.

0

0000

Refer to
Name
and
function
column.

P S

Advertising