2 status display – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 298

Advertising
background image

15 - 53

15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

15.5.2 Status display

(1) Status display list

The following table lists the servo statuses that may be shown:

Name

Symbol

Unit

Description

Display

range

Cumulative feedback
pulses

C

pulse

Feedback pulses from the servo motor encoder are counted and
displayed. The value in excess of 99999 is counted, bus since the
servo amplifier display is five digits, it shows the lower five digits of
the actual value. Press the "SET" button to reset the display value to
zero.
Reverse rotation is indicated by the lit decimal points in the upper
four digits.

99999

to

99999

Servo motor speed

r

r/min

The servo motor speed is displayed.
The value rounded off is displayed in 0.1r/min.

5400

to

5400

(1) Torque control mode

Analog speed limit (VLA) voltage is displayed.

Analog speed
command voltage
Analog speed limit
voltage

F

V

(2) Speed control mode

Analog speed command (VC) voltage is displayed.

10.00

to

10.00

U

V

(1) Position control mode, speed control mode

Analog torque limit (TLA) voltage is displayed.

0

to

10V

Analog torque
command voltage
Analog torque limit
voltage

(2) Torque control mode

Analog torque command (TLA) voltage is displayed.

10

to

10V

Regenerative load
ratio

L

%

The ratio of regenerative power to permissible regenerative power is
displayed in %.

0

to

100

Effective load ratio

J

%

The continuous effective load torque is displayed.
The effective value in the past is seconds is displayed relative to the
rated torque of 100%.

0

to

300

Peak load ratio

b

%

The maximum torque generated during acceleration/deceleration, etc.
The highest value in the past 15 seconds is displayed relative to the
rated torque of 100%.

0

to

400

Instantaneous torque

T

%

Torque that occurred instantaneously is displayed.
The value of the torque that occurred is displayed in real time
relative to the rate torque of 100%.

0

to

400

Within one-revolution
position low

Cy1

pulse

Position within one revolution is displayed in encoder pulses.
The value returns to 0 when it exceeds the maximum number of
pulses.
The value is incremented in the CCW direction of rotation.

0

to

99999

Within one-revolution
position high

Cy2

100

pulse

The within one-revolution position is displayed in 100 pulse
increments of the encoder.
The value returns to 0 when it exceeds the maximum number of
pulses.
The value is incremented in the CCW direction of rotation.

0

to

1310

Load inertia moment
ratio

dC

0.1

Times

The estimated ratio of the load inertia moment to the servo motor
shaft inertia moment is displayed.

0.0

to

300.0

Bus voltage

Pn

V

The voltage (across P-N) of the main circuit converter is displayed.

0

to

450