2 lists, Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 87

Advertising
background image

5 - 2

5. PARAMETERS

5.1.2 Lists

POINT

For any parameter whose symbol is preceded by *, set the parameter
value and switch power off once, then switch it on again to make that
parameter setting valid.

The symbols in the control mode column of the table indicate the following
modes:
P : Position control mode
S : Internal speed control mode

(1) Item list

No.

Symbol

Name

Control

mode

Initial

value

Unit

Customer

setting

0

*STY

Control mode ,regenerative brake option selection

P S

(Note 1)

1

*OP1

Function selection 1

P S

0002

2

ATU

Auto tuning

P S

0105

3

CMX

Electronic gear numerator

P

1

4

CDV

Electronic gear denominator

P

1

5

INP

In-position range

P

100

pulse

6

PG1

Position loop gain 1

P

35

rad/s

7

PST

Position command acceleration/deceleration time constant
(Smoothing)

P

3

ms

8

SC1

Internal speed command 1

S

100

r/min

9

SC2

Internal speed command 2

S

500

r/min

10

SC3

Internal speed command 3

S

1000

r/min

11

STA

Acceleration time constant

S

0

ms

12

STB

Deceleration time constant

S

0

ms

13

STC

S-pattern acceleration/deceleration time constant

S

0

ms

14

For manufacturer setting

0

15

*SNO Station number setting

P S

0

station

16

*BPS

Serial communication function selection, alarm history clear

P S

0000

17

MOD

Analog monitor output

P S

0100

18

*DMD Status display selection

P S

0000

B

asi

c p

ara

m

et

ers

19

*BLK Parameter block

P S

0000