10 - 6

10. TROUBLESHOOTING

10.2.2 Remedies for alarms

CAUTION

When any alarm has occurred, eliminate its cause, ensure safety, then reset the

alarm, and restart operation. Otherwise, injury may occur.

POINT

When any of the following alarms has occurred, always remove its cause
and allow about 30 minutes for cooling before resuming operation. If
operation is resumed by switching power off, then on to reset the alarm, the
servo amplifier and servo motor may become faulty.

Regenerative error (AL.30)
Overload 1 (AL.50)
Overload 2 (AL.51)

The alarm can be deactivated by switching power off, then on press the
"SET" button on the current alarm screen or by turning on the reset signal
(RES). For details, refer to Section 10.2.1.

When an alarm occurs, the trouble signal (ALM) switches off and the dynamic brake is operated to stop
the servomotor. At this time, the display indicates the alarm No.
The servo motor comes to a stop. Remove the cause of the alarm in accordance with this section. The
optional servo configuration software may be used to refer to the cause.

Display

Name

Definition

Cause

Action

1. Power supply voltage is low.
2. There was an instantaneous

control power failure of 60ms or
longer.

3. Shortage of power supply capacity

caused the power supply voltage to
drop at start, etc.

4. Power was restored after the bus

voltage had dropped to 200VDC.

Review the power supply.

AL.10

Undervoltage

Power supply
voltage dropped to
160VAC or less.

5. Faulty parts in the servo amplifier Change the servo amplifier.

AL.12

Memory error 1 RAM, memory fault

AL.13

Clock error

Printed board fault

Faulty parts in the servo amplifier

Change the servo amplifier.

1. Faulty parts in the servo amplifier

AL.15

Memory error 2 EEP-ROM fault

2. The number of write times to EEP-

ROM exceeded 100,000.

Change the servo amplifier.

1. Encoder connector (CN2)

disconnected.

Connect correctly.

2. Encoder fault

Change the servo motor.

AL.16

Encoder error 1 Communication

error occurred
between encoder
and servo amplifier. 3. Encoder cable faulty

(Wire breakage or shorted)

Repair or change cable.

AL.17

Board error

CPU/parts fault

AL.19

Memory error 3 ROM memory fault

Faulty parts in the servo amplifier

Change the servo amplifier.

Advertising