7 input power supply circuit, 1 connection example, Signals and wiring – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 65: Caution

Advertising
background image

3 - 34

3. SIGNALS AND WIRING

3.7 Input power supply circuit

CAUTION

When the servo amplifier has become faulty, switch power off on the servo

amplifier power side. Continuous flow of a large current may cause a fire.

Use the trouble signal to switch power off. Otherwise, a regenerative brake

transistor fault or the like may overheat the regenerative brake resistor, causing a

fire.

POINT

The power supply connector (CNP1) is optional. Purchase it without fail.

3.7.1 Connection example

Wire the power supply and main circuit as shown below so that the servo-on signal turns off as soon as
alarm occurrence is detected and power is shut off.
A no-fuse breaker (NFB) must be used with the input cables of the power supply.

(1) For 3-phase 200 to 230VAC power supply

3-phase
200 to 230 VAC

Emergency stop

Servo-on

Trouble

Servo amplifier

External

power

supply

24VDC

(Note)

RA

OFF

ON

MC

MC

SK

NFB

MC

L

1

L

2

L

3

VIN

EMG

SON

SG

ALM

SG

RA

CNP1

P

D

C

Note: To use the built-in regenerative resistor, be sure to connect across P and D of the power supply connector (CNP1).

Emergency
stop

Advertising