Signals and wiring – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 76

Advertising
background image

3 - 45

3. SIGNALS AND WIRING

3.11 Servo amplifier connectors (CNP1, CNP2) wiring method (When MR-ECPN1-B and MR-ECPN2-B of

an option are used.)

(1) Termination of the cables

Solid wire: After the sheath has been stripped, the cable can be used as it is. (Cable size: 0.2 to
2.5mm

2

)

8 to 9 mm

Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to

avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder
the core as it may cause a contact fault. (Cable size: 0.2 to 2.5mm

2

)Alternatively, a bar

terminal may be used to put the wires together.(Phoenix contact make)

Cable size

Bar terminal type

[mm

2

]

AWG

For 1 cable

For 2 cables

Crimping tool

Maker

BT1.25-9-1

NH1

NICHIFU

1.25

16

TUB-1.25

YHT-2210

JST

AI-TWIN2 1.5-8BK

1.5

16

AI1.5-8BK

AI-TWIN2 1.5-12BK

CRIMPFOX-UD6

Phoenix Contact

BT2-9-1

NH1

NICHIFU

2

14

TUB-2

YHT-2210

JST

2.5

14

AI2.5-8BU
AI2.5-8BK-1000

AI-TWIN2 2.5-10BU
AI-TWIN2 2.5-13BU

CRIMPFOX-UD6

Phoenix Contact

Advertising