Servo motor – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 227

Advertising
background image

14 - 20

14. SERVO MOTOR

HC-SFE Series

(Middle inertia, middle capacity)

Servo Motor

Item

52

102

152

202

Applicable servo
amplifier/drive unit

MR-E- A

70

100

200

200

Rated output

[kW]

0.5

1.0

1.5

2.0

[N m]

2.39

4.78

7.16

9.55

(Note 1,11)
Continuous
duty

Rated
torque

[oz in]

339

677

1015

1353

(Note 1)

Rated speed

[r/min]

2000

Maximum speed

[r/min]

3000

2500

Permissible instantaneous speed [r/min]

345

2850

[N m]

7.16

14.4

21.6

28.5

Maximum torque

[oz in]

1015

2041

3061

4039

Power rate at continuous rated torque

[kW/s]

8.7

16.7

25.6

21.5

J

[ 10

4

kg m

2

]

6.6

13.7

20.0

4.5

(Note 3)
Inertia moment

WK

2

[oz in

2

]

36.1

74.9

109

232

(Note 2)

Recommended ratio of load inertia

moment to servo motor shaft inertia moment

15 times or less

Servo amplifier' built-
in regenerative brake
resistor

56

54

136

64

MR-RB032(30W)

165

80

MR-RB12(100W)

560

270

MR-RB32(300W)

810

MR-RB30(300W)

408

192

(Note4)
Regenerati
ve brake
duty
[times/min]

MR-E
series

MR-RB50(500W)

680

320

Power supply capacity

Refer to "Power supply equipment capacity and generated loss of servo amplifiers"
in Servo Amplifier Instruction Manual.

Rated current

[A]

3.2

6

9

11

Maximum current

[A]

9.6

18

27

33

Speed/position detector

Encoder

(resolution: 10000 pulse/rev)

Accessories

Encoder Oil seal

Insulation class

Class F

Structure

Totally-enclosed, self-cooled

(protection type: IP65(Note 8))

(Note 7)

Environmental conditions

Refer to section 2.1

[kg]

5.0

7.0

9.0

12.0

(Note 3)

Weight

[lb]

11.0

15.4

19.8

26.5

Note: 1. When the power supply voltage drops, we cannot guarantee the output and rated speed.

2. If the load inertia moment ratio exceeds the indicated value, please consult us.

3. When the servo motor is equipped with electromagnetic brake, refer to section 14.8.When the servo motor is equipped with

reduction gear, please consult us.

4. The regenerative brake duty indicated is the permissible duty when the servo motor running without load at the rated speed is

decelerated to a stop. When a load is connected, the value in the table is multiplied by 1/(m 1), where m load inertia

moment/motor inertia moment. At the speed higher than the rated, the permissible number of times is in inverse proportion to

the square of (running speed/rated speed). When the running speed varies frequently or when the regenerative mode

continues as in vertical feed, calculate regenerative heat generated during operation. Provisions must be made to keep this

generated heat below the permissible value.

5. If the effective torque is within the rated torque range, there are no restrictions on the regenerative duty. Note that the

recommended load inertia moment ratio is 15 times or less.

6. Except for the shaft-through portion and connector end.

7. When the equipment is to be used in places where it is subjected to oil and/or water, such as on machine field sites, optional

features apply to the equipment. Please contact.

8. When the servo motor is provided with the reduction gear, the protection type of the reduction gear section is IP44.

9. At the load inertia moment ratio of 5 times or less, there are no restrictions on the regenerative duty if the effective torque is

within the rated torque range.

10. The regenerative brake duty of the 400W or less servo amplifier may vary under the influence of the power supply voltage

because of the large ratio of the energy for charging the electrolytic capacitor in the servo amplifier.

Advertising