Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 88

Advertising
background image

5 - 3

5. PARAMETERS

No.

Symbol

Name

Control

mode

Initial

value

Unit

Customer

setting

20

*OP2

Function selection 2

P S

0000

21

*OP3

Function selection 3 (Command pulse selection)

P

0000

22

*OP4

Function selection 4

P S

0000

23

FFC

Feed forward gain

P

0

%

24

ZSP

Zero speed

P S

50

r/min

25

For manufacturer setting

0

26

For manufacturer setting

100

27

*ENR Encoder output pulses

P S

4000

pulse

/rev

28

TL1

Internal torque limit 1

P S

100

%

29

For manufacturer setting

0

30

For manufacturer setting

0

31

MO1

Analog monitor 1 offset

P S

0

mV

32

MO2

Analog monitor 2 offset

P S

0

mV

33

MBR

Electromagnetic brake sequence output

P S

100

ms

34

GD2

Ratio of load inertia moment to servo motor inertia moment

P S

70

0.1

times

35

PG2

Position loop gain 2

P

35

rad/s

36

VG1

Speed loop gain 1

P S

177

rad/s

37

VG2

Speed loop gain 2

P S

817

rad/s

38

VIC

Speed integral compensation

P S

48

ms

39

VDC

Speed differential compensation

P S

980

40

For manufacturer setting

0

41

*DIA

Input signal automatic ON selection

P S

0000

42

*DI1

Input signal selection 1

P S

0002

43

*DI2

Input signal selection 2 (CN1-4)

P S

0111

44

*DI3

Input signal selection 3 (CN1-3)

P S

0882

45

*DI4

Input signal selection 4 (CN1-5)

P S

0995

46

*DI5

Input signal selection 5 (CN1-6)

P S

0000

47

*DI6

Input signal selection 6 (CN1-7)

P S

0000

48

*LSPN LSP LSN input terminals selection

P S

0403

E

xp

ansi

on

p

ara

m

et

ers

1

49

*DO1 Output signal selection 1

P S

0000

Advertising