Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 101

Advertising
background image

5 - 16

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial
value

Unit

Setting

range

Control

mode

E

xp

ansi

on

p

ara

m

et

ers

1

43

*DI2

Input signal selection 2 (CN1-4)

Allows any input signal to be assigned to CN1-pin 4.
Note that the setting digit and assigned signal differ according to the
control mode.

Position
control mode

Input signals of
CN1-pin 4
selected.

Internal speed
control mode

0 0

Signals that may be assigned in each control mode are indicated
below by their symbols.
Setting of any other signal will be invalid.

Set value

(Note) Control mode

P

S

0
1
2
3
4
5
6
7
8
9

SON

SON

RES

RES

PC

PC

SP1
SP2
ST1
ST2

CR

CR

A

SP3

B
C
D

TL1

E

CDP

CM1
CM2
TL1
CDP

F

Note: P: Position control mode

S: Internal speed control mode

This parameter is unavailable when parameter No.42 is set to assign
the control change (LOP) to CN1-pin 4.
This parameter is unavailable when parameter No. 48 is set to assign
the Forward rotation stroke end (LSP) and Reverse rotation stroke end
(LSN) to be assigned to CN1-pin 4.

0111

Refer to
Name
and
function
column.

P S