3. SIGNALS AND WIRING

3.4.3 Position/internal speed control change mode

Set "0001" in parameter No. 0 to switch to the position/internal speed control change mode. This function
is not available in the absolute position detection system.
(1) Control change (LOP)

Use control change (LOP) to switch between the position control mode and the internal speed control
mode from an external contact. Relationships between LOP-SG status and control modes are indicated
below:

(Note) LOP

Servo control mode

0

Position control mode

1

Speed control mode

Note.0: LOP-SG off (open)

1: LOP-SG on (short)

The control mode may be changed in the zero-speed status. To ensure safety, change control after the
servo motor has stopped. When position control mode is changed to speed control mode, droop pulses are
reset.
If the signal has been switched on-off at the speed higher than the zero speed and the speed is then
reduced to the zero speed or less, the control mode cannot be changed. A change timing chart is shown
below:

ON

OFF

ON

OFF

Position

control mode

Internal speed

control mode

Servo motor speed

Zero speed (ZSP)

Control change (LOP)

Zero speed
level

(Note)

Note: When ZSP is not on, control cannot be changed if LOP is switched on-off.
If ZSP switches on after that, control cannot not be changed.

(Note)

Position

control mode

(2) Torque limit in position control mode

As in Section 3.4.1 (5).