Signals and wiring, 1 standard connection example – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 253

Advertising
background image

15 - 8

15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

15.2. Signals and wiring

15.2.1 Standard connection example

(1) Speed control mode

1

9

12

10m (32ft) or less

RA1

RA2

8

4

3

5

6

7

EMG

SON

ST1

ST2

LSP

LSN

SG

13

ALM

ZSP

Servo amplifier

(Note 1)

CN3

(Note 8)
CN1

Trouble
(Note 6)

Zero speed

VIN

(Note 2, 4)

CN1

(Note 8)

4

3

SD

6

MO1

LG

A

A

2m (6.5ft) or less

Plate

CN3

(Note 8)

20

19

21

17

16

18

LZ

LZR

LA

LAR

LB

LBR

LG

OP

SD

14

15

Encoder Z-phase pulse

(differential line driver)

11

10

SA

RD

RA5

RA4

Speed reached

Ready

13

SG

Plate

External

power

supply

24VDC

(Note 10)

2m (6.5ft) or less

Plate

14

SD

LG

26

VC

2

TLA

Upper limit setting

Upper limit setting

CN1

(Note 8)

Encoder A-phase pulse

(differential line driver)

Encoder B-phase pulse

(differential line driver)

Control common

Encoder Z-phase pulse

(open collector)

(Note 8)

MO2

(Note 3, 5) Emergency stop

Servo-on

Forward rotation start

Reverse rotation start

(Note 5) Forward rotation stroke end

Reverse rotation stroke end

(Note 9)
Servo configuration
software

Personal
computer

(Note 7)
Communication cable

Analog speed command

10V/rated speed

Analog torque limit

10V/max. torque

(Note 7)
Monitor output
Max. 1mA
Reading in
both directions

10k

10k

Use external power

supply ( 15VDC).

Advertising