Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 97

Advertising
background image

5 - 12

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial
value

Unit

Setting

range

Control

mode

22

*OP4 Function selection 4

Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN) off and choose TLC/VLC output.

0 0

How to make a stop when forward
rotation stroke end (LSP)
reverse rotation stroke end (LSN)
is valid. (Refer to Section 5.2.3.)

0: Sudden stop
1: Slow stop

0

0000

Refer to
Name
and
function
column.

P S

23

FFC

Feed forward gain

Set the feed forward gain. When the setting is 100%, the droop pulses

during operation at constant speed are nearly zero. However, sudden

acceleration/deceleration will increase the overshoot. As a guideline,

when the feed forward gain setting is 100%, set 1s or more as the

acceleration/deceleration time constant up to the rated speed.

0

%

0

to

100

P

24

ZSP

Zero speed

Used to set the output range of the zero speed (ZSP).

50

r/min

0

to

10000

P S

25

For manufacturer setting
Don’t change this value by any means.

0

Ex

pan

si

on

par

ame

te

rs

1

26

For manufacturer setting
Don’t change this value by any means.

100

Advertising