MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 260

Advertising
background image

15 - 15

15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

Control

mode

Signal

Symbol

Connec-

tor pin

No.

Functions/Applications

I/O

division

S

T

Used to start the servo motor in any of the following directions:

(Note) Input signals

ST2

ST1

Servo motor starting direction

Forward rotation
start

ST1

CN1

-3

0

0

Stop (servo lock)

0

1

CCW

1

0

CW

1

1

Stop (servo lock)

Reverse rotation
start

ST2

CN1

-5

Note. 0: ST1/ST2-SG off (open)

1: ST1/ST2-SG on (short)

If both ST1 and ST2 are switched on or off during operation, the
servo motor will be decelerated to a stop according to the parameter
No. 12 setting and servo-locked.

DI-1

Used to select any of the following servo motor torque generation
directions:

(Note) Input signals

RS2

RS1

Torque generation direction

Forward rotation
selection

RS1

CN1

-5

0

0

Torque is not generated.

0

1

Forward rotation in driving mode /
reverse rotation in regenerative mode

1

0

Reverse rotation in driving mode /
forward rotation in regenerative mode

1

1

Torque is not generated.

Reverse rotation
selection

RS2

CN1

-3

Note. 0: off

1: on

DI-1

Speed selection 1

SP1

<Speed control mode>

Used to select the command speed for operation.
When using SP1 to SP3, make it usable by making the setting of
parameter No. 43 to 48.

DI-1

(Note) Input signals

Speed selection 2

SP2

SP3

SP2

SP1

Speed command

DI-1

Speed selection 3

SP3

0

0

0

Analog speed command (VC)

DI-1

0

0

1

Internal speed command 1 (parameter No. 8)

0

1

0

Internal speed command 2 (parameter No. 9)

0

1

1

Internal speed command 3 (parameter No. 10)

1

0

0

Internal speed command 4 (parameter No. 72)

1

0

1

Internal speed command 5 (parameter No. 73)

1

1

0

Internal speed command 6 (parameter No. 74)

1

1

1

Internal speed command 7 (parameter No. 75)

Note 0: SP1/SP2/SP3-SG off (open)

1: SP1/SP2/SP3-SG on (short)

<Torque control mode>

Used to select the limit speed for operation.
When using SP1 to SP3, make it usable by making the setting of
parameter No. 43 to 48.

(Note) Input signals

SP3

SP2

SP1

Speed liimit

0

0

0

Analog speed limit (VLA)

0

0

1

Internal speed limit 1 (parameter No. 8)

0

1

0

Internal speed limit 2 (parameter No. 9)

0

1

1

Internal speed limit 3 (parameter No. 10)

1

0

0

Internal speed limit 4 (parameter No. 72)

1

0

1

Internal speed limit 5 (parameter No. 73)

1

1

0

Internal speed limit 6 (parameter No. 74)

1

1

1

Internal speed limit 7 (parameter No. 75)

Note 0: SP1/SP2/SP3-SG off (open)

1: SP1/SP2/SP3-SG on (short)