µPD750008 USER'S MANUAL

Any line carrying a high pulsating current must be kept away as far as possible.

• The grounding point of the capacitor of the oscillator must have the same

potential as that of V

SS

. It must not be grounded to a grounding pattern carry

ing a high current.

• No signal must be taken directly from the resonator.

The subsystem clock oscillator has low amplification to minimize current con-

sumption. For this reason, more malfunctions can occur due to noise than the

main system clock oscillator. So pay special attention to wiring when using the

subsystem clock.

Figure 5-16 gives examples of oscillator connections which should be avoided.

Figure 5-16. Examples of Oscillator Connections Which Should Be Avoided (1/2)

(a) The wiring is too long.

(b) The signal lines cross.

Remark When wiring the subsystem clock, read X1 and X2 as XT1 and XT2 respectively. In this case,

a resistor must be added to XT2 in series.