288

µPD750008 USER'S MANUAL

B

C

3

0

0

D

3

0

E

3

0

11

8 7

4 3

0

12

PC

BR BCDE

Function: For the µPD750008 PC

12-0

<– BCDE

Branches to the address specified by the program counter whose bits have been replaced with the contents

of the B

0

, C, D, and E registers.

BR BCXA

Function: For the µPD750008 PC

12-0

<– BCXA

Branches to the address specified by the program counter whose bits have been replaced with the contents

of the B

0

, C, X, and A registers.

TBR addr

Function:

Assembler pseudo instruction of the GETI instruction for table definition. This instruction is

used to replace a 3-byte BR instruction with a 1-byte GETI instruction. The 12-bit address data

must be coded in addr. For detailed information, refer to RA75X Assembler Package User’s

Manual: Language (EEU-1363).

Remark "Function" in this section is applicable to the µPD750008 whose program counter consists of

13 bits (addr = 0000H to 1FFFH).

However, this is also applicable to the µPD750004 whose program counter consists of 12

bits (addr = 0000H to 0FFFH), the µPD750006 whose program counter consists of 13 bits

(addr = 0000H to 17FFH), and the µPD75P0016 whose program counter consists of 14 bits

(addr = 0000H to 3FFFH).

B

C

3

0

0

X

3

0

A

3

0

11

8 7

4 3

0

12

PC

Advertising