5.1.3 Digital I/O Port Manipulation Instructions

All I/O ports contained in the µPD750008 are mapped to data memory space, so that all data memory

manipulation instructions can be used. Table 5-3 lists the instructions that are particularly useful for I/O pin

manipulation and their application ranges.

(1) Bit manipulation instructions

For digital I/O ports PORT0 to PORT8, specific address bit direct addressing (fmem.bit) and specific

address bit register indirect addressing (pmem.@L) can be used. This means that bit manipulation can

be freely performed for these ports regardless of MBE and MBS settings.

Example

P50 is ORed with P41, then the result is output to P61.

SET1

CY

; CY <– 1

AND1

CY,PORT5.0

; CY <– CY

P50

OR1

CY,PORT4.1

; CY <– CY

P41

SKT

CY

BR

CLRP

SET1

PORT6.1

; P61 <– 1

.

.

.

CLRP :

CLR1

PORT6.1

; P61 <– 0

(2) 4-bit manipulation instructions

All 4-bit memory manipulation instructions including the IN, OUT, MOV, XCH, ADDS, and INCS

instructions can be used. However, before these instructions can be executed, memory bank 15 must

be selected.

Examples 1. The contents of the accumulator are output to port 3.

SEL

MB15

; or CLR1 MBE

OUT

PORT3,A

2. The value of the accumulator is added to the data output on port 5, then the result is output.

SET1

MBE

SEL

MB15

MOV

HL,#PORT5

ADDS

A,@HL

; A <– A+PORT5

NOP

MOV

@HL,A

; PORT5 <– A

3. Whether the data on port 4 is greater than the value of the accumulator is tested.

SET1

MBE

SEL

MB15

MOV

HL,#PORT4

SUBS

A,@HL

; A < PORT4

BR

NO

; NO

; YES

Advertising