2 8

µPD750008 USER'S MANUAL

Example 2. The data memory of 00H to FFH is cleared to 0.

CLR1

RBE

CLR1

MBE

MOV

XA,#00H

MOV

HL,#04H

LOOP:

MOV

@HL,A

; (HL) <– A

INCS

HL

; HL <– HL + 1

BR

LOOP

Figure 3-3. Updating Static RAM Addresses

INCS D

DECS D

INCS L

DECS L

INCS D

DECS D

INCS E

DECS E

INCS H

DECS H

INCS L

DECS L

INCS H

DECS H

x 0H

0 x H

F x H

@DL

4-bit transfer

@DE

4-bit transfer

@HL

4-bit
manipulation

8-bit
manipulation

@H + mem.bit

Bit manipulation

Direct
addressing
Bit manipulation
4-bit transfer
8-bit transfer

x FH

DECS DE

INCS DE

DECS HL

INCS HL

Automatic
decrement

Automatic
increment