Show network, Show network -24 – NETGEAR 7300 Series User Manual

Page 90

Advertising
background image

User Manual for the NETGEAR 7300 Series Layer 3 Managed Switch Software

8-24

Switching Commands

202-10009-01_060204

Agetime

Displays the address aging timeout for the associated forwarding
database in IVL. In an SVL system, this will display the system's
address aging timeout value in seconds.

show network

This command displays configuration settings associated with the switch's network interface. The
network interface is the logical interface used for in-band connectivity with the switch via any of
the switch's front panel ports. The configuration parameters associated with the switch's network
interface do not affect the configuration of the front panel ports through which traffic is switched
or routed.

Format

show network

Mode

Privileged EXEC and User EXEC

IP Address

The IP address of the interface. The factory default value is
0.0.0.0

Subnet Mask

The IP subnet mask for this interface. The factory default value is
0.0.0.0

Default Gateway

The default gateway for this IP interface. The factory default
value is 0.0.0.0

Burned In MAC Address The burned in MAC address used for in-band connectivity.

Locally Administered MAC Address If desired, a locally administered MAC address

can be configured for in-band connectivity. To take effect, 'MAC
Address Type' must be set to 'Locally Administered'. Enter the
address as twelve hexadecimal digits (6 bytes) with a colon
between each byte. Bit 1 of byte 0 must be set to a 1 and bit 0 to a
0, i.e. byte 0 should have the following mask 'xxxx xx10'. The
MAC address used by this bridge when it must be referred to in a
unique fashion. It is recommended that this be the numerically
smallest MAC address of all ports that belong to this bridge.
However it is only required to be unique. When concatenated
with dot1dStpPriority a unique BridgeIdentifier is formed which
is used in the Spanning Tree Protocol.

MAC Address Type

Specifies which MAC address should be used for in-band con-
nectivity. The choices are the burned in or the Locally Adminis-
tered address. The factory default is to use the burned in MAC
address.