Snmpv2c with traps, Snmpv1 with traps – 3Com Wireless LAN WX1200 User Manual

Page 184

Advertising
background image

184

C

HAPTER

7: IP S

ERVICES

C

OMMANDS

„

ip-addr[:udp-port-number]

— IP address of the server. You also

can specify the UDP port number to send notifications to.

„

community-string

— Community string.

„

profile profile-name

— Notification profile this SNMP user will use

to specify the notification types to send or drop.

„

retries num

— Notification profile this SNMP user will use to specify

the notification types to send or drop.

„

timeout num

— Specifies the number of seconds MSS waits for

acknowledgement of a notification. You can specify from 1 to 5
seconds.

SNMPv2c with Traps

To configure a notification target for traps from SNMPv2c, use the
following command:

Syntax

set snmp notify target target-num ip-addr[:udp-port-number]

v2c community-string trap
[profile
profile-name]

„

target-num

— ID for the target. This ID is local to the WX switch and

does not need to correspond to a value on the target itself. You can
specify a number from 1 to 10.

„

ip-addr[:udp-port-number]

— IP address of the server. You also

can specify the UDP port number to send notifications to.

„

community-string

— Community string.

„

profile profile-name

— Notification profile this SNMP user will use

to specify the notification types to send or drop.

SNMPv1 with Traps

To configure a notification target for traps from SNMPv1, use the
following command:

Syntax

set snmp notify target target-num ip-addr[:udp-port-number]

v1 community-string
[profile
profile-name]

„

target-num

— ID for the target. This ID is local to the WX switch and

does not need to correspond to a value on the target itself. You can
specify a number from 1 to 10.

„

ip-addr[:udp-port-number]

— IP address of the server. You also

can specify the UDP port number to send notifications to.