set snmp usm

Creates a USM user for SNMPv3.

This command does not apply to SNMPv1 or SNMPv2c. For these SNMP
versions, use the set snmp community command to configure
community strings.

Syntax

set snmp usm usm-username

snmp-engine-id {ip ip-addr | local | hex hex-string}
access {read-only | read-notify | notify-only | read-write |
notify-read-write}
auth-type {none | md5 | sha} {auth-pass-phrase
string |
auth-key
hex-string}
encrypt-type {none | des | 3des | aes} {encrypt-pass-phrase
string | encrypt-key hex-string}

„

usm-username

— Name of the SNMPv3 user. Specify between 1 and

32 alphanumeric characters, with no spaces.

„

snmp-engine-id {ip ip-addr | local | hex hex-string} —

Specifies a unique identifier for the SNMP engine. To send informs,
you must specify the engine ID of the inform receiver. To send traps
and to allow get and set operations and so on, specify local as the
engine ID.

„

hex hex-string

—ID is a hexadecimal string.

„

ip ip-addr

—ID is based on the IP address of the station running

the management application. Enter the IP address of the station.
MSS calculates the engine ID based on the address.

„

local

— Uses the value computed from the switch’s system IP address.