When copy pairs do not change to hold status – HP XP Racks User Manual

Page 447

Advertising
background image

Case where the conditions described in No. 2 are not satisfied:

Some Cnt Ac-S Z copy pairs have different copy direction from others.

2.

Execute the YKEWIT GOTO(HOLD) command.

If all conditions in

Table 108 (page 446)

are met, copy pairs will automatically change to

HOLD status after a brief interval.

When all conditions in

Table 108 (page 446)

are met but copy pairs do not change from the

HOLDTRNS status to the HOLD status, execute the procedure in

“When Copy Pairs Do Not

Change to HOLD Status” (page 447)

.

When Copy Pairs Do Not Change to HOLD Status

In the procedure in

“Managing the HOLDTRNS Status” (page 446)

, when all conditions for changing

to the HOLD status are met but copy pairs do not change to the HOLD status, an error might occur
in the inter-DKC path to which a delta sync pair, P-VOL and S-VOL belong, or the copy direction
of all Cnt Ac-J Z copy pairs is not from the primary site to the remote site (when using failback, the
direction from the local site to the remote site). In this case, recover the failed path, or modify the
copy direction of all Cnt Ac-J Z pairs to be from the primary site toward the remote site (from the

Using a Delta Resync Configuration 447