Used to specify the identification name that was specified in the START command when BCM
Monitor was started.

Example

To forcibly stop the BCM Monitor instance whose identification name is YK, enter the following
command:

CANCEL YK

Return codes for BCM Monitor

“Return codes issued when BCM Monitor is stopped” (page 680)

shows the return codes issued

when BCM Monitor stops.

Table 115 Return codes issued when BCM Monitor is stopped

Meaning

Return Code (Decimal
Format)

BCM Monitor terminated normally.

0

The child task terminated abnormally.

4

One of the following errors occurred while analyzing the BCM Monitor parameter files:

8

An attempt to access the BCM Monitor parameter files failed.

The settings specified for the BCM Monitor parameter files are invalid.

GETMAIN

failed.

One of the following errors occurred when not analyzing the BCM Monitor parameter files:

12

An error occurred when specifying the initial settings.

No profile has been defined in the RACF FACILITY class.

BCM Monitor has not started via IKJEFT01.

GETMAIN

failed.

BCM Monitor was stopped by a startup action, an action, or an error action with EXIT
specified. The return code specified for EXIT will be issued.

Other

Operator commands available in BCM Monitor

BCM Monitor supports the operator commands shown in

“List of functions of BCM Monitor

commands” (page 680)

. By executing these operator commands, you can change the behavior or

check the status of BCM Monitor while it is running. Operator commands are executed after all
the actions BCM Monitor is currently performing are finished.

Table 116 List of functions of BCM Monitor commands

Function

Command Name

Displays the status of BCM Monitor

DISPLAY

Outputs the information for the copy groups whose IDs are specified in the YKMONCG file

REPORT

Modifies the values specified in the BCM Monitor parameter files after BCM Monitor has
started

SET

Puts BCM Monitor to sleep

SLEEP

Wakes up BCM Monitor

WAKEUP

For the symbols used in the explanation on the format of operator commands, see

“Conventions

in syntax explanations” (page 746)

.