HP Onboard Administrator User Manual
Page 122

Configuring the HP BladeSystem c7000 enclosure and enclosure devices 122
SNMP Users tab
To remove a current SNMP user, select the check box, and click Delete.
To add a new SNMP user, click New. The Add SNMP User screen appears.
Adding SNMP Users
To set up your new SNMP user's information, use the following fields.
Field
Possible value
Description
User Name
A unique string containing 1 to 32
characters; all characters must be
either alphanumeric or dash or
underscore and the first character must
be alphabetic.
User account name used for SNMPv3
queries, traps, and informs. Each
username/engine id pair must be unique
and cannot be duplicated.
Engine ID
Must begin with '0x' followed by an
even number of up to 64 hexadecimal
digits.
The engine ID is combined with the user
name to create a SNMPv3 user for each
enclosure. When the engine ID is unique
to an enclosure, users with the same
name on different enclosures are unique.
Defaults to a unique Engine ID for the
enclosure. Only used for creating remote
accounts used with INFORM messages.
Access Mode
•
Read Only
•
Read Write
Only applies to local users. Specifies this
user has read/write access to the OID
tree. If not specified the user will have
read-only access.
Minimum Security
•
noAuthNoPriv—Allows
unauthenticated operations
•
authNoPriv—Requires
authentication
•
authPriv—Requires encryption
Only applies to local users. Minimal
level of security required for operation.
By default, operation is required to be
signed but not encrypted (authNoPriv).