Power errors, Cooling errors, Location errors – HP Onboard Administrator User Manual

Page 47: Configuration errors

Advertising
background image

HP BladeSystem Insight Display 47

Fix THIS—Suggests corrective action to clear the current error.

Next Alert—Displays the next alert, or if none exist, displays the Health Summary screen.

Previous Alert—Displays the previous alert.

Power errors

Power errors can occur because of insufficient power to bring up an enclosure. Power errors can occur on
server blades, storage blades, or interconnect modules.
To correct a power error:

1.

Use the arrow buttons to navigate to Fix This, and press OK.

2.

Review and complete the corrective action suggested by the Insight Display. In most cases, you must
either add power supplies to the enclosure or remove the indicated components.

Cooling errors

Cooling errors occur when too few fans are installed in the enclosure or when the existing fans are not

installed in an effective configuration. Cooling errors can occur on server blades, storage blades, or

interconnect modules.
To correct a cooling error:

1.

Use the arrow buttons to navigate to Fix This, and press OK.

2.

Review and complete the corrective action suggested by the Insight Display. In most cases, you must
either add fans to the enclosure, correct the fan configuration, or remove the indicated components.

Location errors

Location (installation) errors occur when the component is not installed in the appropriate bay. Location

errors can occur on server blades, storage blades, power supplies, and fans.
To correct a location error:

1.

Use the arrow buttons to navigate to Fix This, and press OK.

2.

Review and complete the corrective action suggested by the Insight Display. Remove the indicated
component, and install it into the correct bay. The Insight Display will indicate the correct bay number.

Configuration errors

Configuration errors can occur if the interconnect modules are installed in the wrong bays or if mezzanine
cards are installed in the wrong connectors in the server blade. Configuration errors can occur on server

blades and interconnect modules.
To correct a configuration error:

1.

Use the arrow buttons to navigate to Fix This, and press OK.

2.

Review and complete the corrective action suggested by the Insight Display. Depending on the error
received, do one of the following:

o

Remove the indicated interconnect module and install it into the correct bay (the Insight Display
indicates the correct bay).

Advertising