Using the command line interface 293

Using the command line interface

Command line overview

The Onboard Administrator CLI is available from the Onboard Administrator serial port, management port,
service port or c3000 KVM Module option and provides access to all Onboard Administrator commands

and information.
The CLI user must provide a valid username/password to log into Onboard Administrator. The CLI is

available for both local user accounts and LDAP users. Two-factor authentication is not available for the CLI.
Access to the Onboard Administrator CLI from either the Onboard Administrator Ethernet management port

or service port requires that telnet or SSH protocols are enabled on Onboard Administrator.
Access to the Onboard Administrator CLI from the c3000 KVM Module or Onboard Administrator serial port

is always available independent of the telnet or SSH protocol setting.
The Onboard Administrator serial port must be used for Onboard Administrator firmware flash recovery or
Administrator lost password recovery.
The Onboard Administrator serial port speed is fixed at 9600, N, 8, 1.
For more information about the Command Line Interface, see the HP BladeSystem Onboard Administrator

Command Line Interface User Guide.

Setting up Onboard Administrator using the CLI

1.

Connect to the Onboard Administrator CLI using the serial port, management port, service port, or
c3000 KVM Module option.

2.

Log in to the Onboard Administrator with the "Administrator" user account and the OA dogtag
password.

3.

Set Onboard Administrator name: "SET OA NAME 1 <name>".

4.

If a redundant Onboard Administrator is present, set the name to: "SET OA NAME 2 <name>".

5.

Configure Onboard Administrator IP address

a.

Select whether to use either the OA1/OA2 IP address or Enclosure IP address.

b.

Configure OA1 IP address as static or DHCP. Example for static: "SET IPCONFIG STATIC 1
<ipaddress><netmask>"

6.

If a redundant Onboard Administrator is present: "SET IPCONFIG STATIC 2 <ip address> <netmask>".

7.

Set Onboard Administrator gateway: "SET OA GATEWAY 1 <ip address>.

8.

If a redundant Onboard Administrator is present: "SET OA GATEWAY 2 <ip address>.

9.

Set the iLO IP address: "SET EBIPA SERVER <ip address> <netmask>. Allocate each IP address needed
(up to 32) consecutive static IP addresses.

10.

If a gateway exists on the management network, set the iLO gateway to the IP address: SET EBIPA
SERVER GATEWAY <ip address>.

11.

Start EBIPA FOR iLO: "ENABLE EBIPA SERVER".