Editing the web proxy settings – HP Onboard Administrator User Manual

Page 161

Advertising
background image

Configuring the HP BladeSystem c7000 enclosure and enclosure devices 161

Editing the web proxy settings

Proxy settings must be maintained to enable your enclosure to continue to send Remote Support data to HP.

If the proxy settings change, use the following procedure to edit them:

1.

Navigate to the Enclosure Information>Enclosure Settings>Remote Support page.

2.

Update the following settings, as needed:

o

Web Proxy Server—Enter the web proxy server in the format http://<hostname or IP address>.

o

Web Proxy Port

o

Web Proxy Username

o

Web Proxy Password

3.

Click Apply.

Registering for Insight Remote Support by using Central Connect

Use the following procedure to register an HP BladeSystem c-Class enclosure for Central Connect Remote

Support:

1.

Verify that the system meets the prerequisites for using Insight Remote Support. For more information,
see the "Prerequisites" section.

2.

Navigate to the Enclosure Information>Enclosure Settings>Network Access (on page

114

) page and

click the Protocol tab.

3.

Verify that the Enable XML Reply check box is selected.
If this check box is not selected, the Insight RS hosting device cannot collect data from the Onboard
Administrator.

4.

Navigate to the Enclosure Information>Enclosure Settings>Remote Support page.

5.

Select Register this enclosure through an HP Insight Remote Support centralized hosting device. The
page updates to show the Central Connect registration options.

6.

Enter the Insight RS hosting device host name or IP address and port number. The default port is 7906.

7.

Click Register. By registering, you agree to send registration, service events, and configuration data to
HP. All data collected and sent to HP will be managed according to the HP Data Privacy Policy. You can
view the HP Data Privacy Policy at the HP website (

http://www.hp.com/go/privacy

). The following

message appears:
Device successfully registered.

8.

Optional: Send a test event to confirm the connection between OA and Insight Remote Support:

a.

Go to Enclosure Settings > Remote Support.

b.

Click the Service Events ("

Insight Remote Support Service Events

" on page

163

) tab.

c.

Click Send Test Event.

Unregistering an HP BladeSystem c-Class enclosure from Direct Connect Remote
Support

1.

Navigate to the Enclosure Information>Enclosure Settings>Remote Support page.

2.

Click Unregister.
The following message appears: Are you sure you want to un-register and disable HP

Insight Remote Support?

Advertising