HP Onboard Administrator User Manual

Page 98

Advertising
background image

Configuring the HP BladeSystem c7000 enclosure and enclosure devices 98

Row

Description

Standby OA Status

The overall status of the Standby Onboard Administrator. Possible values are Absent,

Unknown, OK, Degraded, or Failed.

Power Mode

A user setting to configure the enclosure DC power capacity and the input power

redundancy mode of the enclosure. See Power Management for possible values.

* The enclosure status appears as N/A if the Enable Extended Data on GUI Login Page setting is disabled. This setting
is accessible at Enclosure Settings>Network Access>Anonymous Data.

Enclosure Diagnostic Information
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a

failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.

Row

Description

Device Identification

Data

Information such as model name, part number, serial number, and other information

used to identify the device is checked. This data is also referred to as FRU data. If the

data is not present or not readable by the Onboard Administrator, a device
identification data error displays. Possible values are OK or Error.

Redundancy

Possible values are OK or Error. An error indicates the redundant Onboard

Administrators are having problems syncing up. Check the syslog for errors. Possible

reasons for the error are mismatched firmware or a software or hardware failure.

Location Services

Possible values are OK or Other. Other indicates a location services error has

occurred. Data might be corrupted.

Enclosure Status Overview

Subsystems and Devices Description

Device Bay Overview

The overall status of all device bays. The status is an aggregate status of all the
devices in the enclosure. If more than one device has a status other than OK, then

they are displayed in a list in this table.

Interconnect Bay Overview The overall status of the interconnect bays. The status is an aggregate status of all

the interconnects in the enclosure. If more than one interconnect has a status other
than OK, then they are displayed in a list in this table.

Power Subsystem

The overall status of the Power Subsystem of the enclosure. The status is an

aggregate status of all the power supplies in the enclosure. If more than one power

supply has a status other than OK, then they are displayed in a list in this table.

Thermal Subsystem

The overall status of the Thermal Subsystem of the enclosure. The status is an

aggregate status of all the fans in the enclosure. If more than one fan has a status

other than OK, then they are displayed in a list in this table.