Configuring the HP BladeSystem c7000 enclosure and enclosure devices 168

All Enclosure Firmware Management features are available through both the Onboard Administrator GUI

and CLI. The Onboard Administrator user role and bay permissions control the Enclosure Firmware
Management settings and ability to view the firmware information.

User role

Modify settings or
scheduled update

Initiate manual
discovery or update

View firmware versions

Onboard Administrator

administrator or operator

Yes

Yes, administrator only

Yes

Server administrator or
operator

No

Yes, administrator only

Yes, for permitted server bays

Onboard Administrator
user

No

No

Yes, for permitted bays

Enabling Enclosure Firmware Management

The Enable Enclosure Firmware Management check box globally enables or disables (default setting)

Enclosure Firmware Management. When disabled, you cannot start any manual Enclosure Firmware

Management operations. Any previously configured automatic or scheduled operation does not occur. If the

setting is changed from enabled to disabled, any in-progress Enclosure Firmware Management discoveries
or updates continue until they are finished.

IMPORTANT:

After Enclosure Firmware Management operations (updates and

discoveries) have begun on a server, you cannot stop these operations. Ensure that

your enclosure is IPv6-enabled before using an IPv6 address for the Firmware

Management ISO.

Enclosure Firmware Management is not supported on the following Onboard Administrator hardware

modules:

HP BladeSystem c3000 Onboard Administrator (HP part number 448589-B21, 461514-B21)

HP BladeSystem c7000 Onboard Administrator (HP part number 412142-B21)

Enclosure Firmware Management cannot be enabled unless the active Onboard Administrator hardware

module is supported. If you attempt to enable Enclosure Firmware Management when the active Onboard

Administrator is not supported, an error message appears:

Enclosure Firmware Management is not supported on the active OA hardware

present.

If the standby Onboard Administrator module is unsupported, a warning message appears:

Enclosure Firmware Management is not supported on the standby OA hardware

present. The feature will be disabled if the standby OA becomes Active.

Enclosure Firmware Management will not work reliably and should not be used on slow network links (less

than 100Mbps).
While running Enclosure Firmware Management operations, the Onboard Administrator response time
might be slower than usual, and during brief intervals, enclosure status might be reported as degraded. You

can safely ignore messages or alert conditions of this nature while the operations are in progress.
Enclosure Firmware Management fails on any blade if SSH is disabled in the blade's iLO configuration

settings. By default, SSH is enabled in iLO.