Configuring the HP BladeSystem c7000 enclosure and enclosure devices 245

Column

Description

Interconnect Bay Port

The number of the interconnect bay port in order from 1 to 16

Port Status

Current status of the port

Device Bay

The device bay corresponding with the interconnect port mapping

Server Mezzanine Slot The type of device placed into the mezzanine of the server blade

Server Mezzanine Port The physical port of the mezzanine device

Device ID

The MAC address of the interconnect bay port

Enclosure power management

Power management planning

The power enclosures each contain six power supplies, which are monitored directly by Onboard

Administrator. Up to two power supply enclosures can be connected to a single enclosure.
Onboard Administrator is responsible for calculating the redundancy status, total available power, and total

power consumed. This information is displayed to the user and is used to manage power resources. The

Onboard Administrator power subsystem displays include status and information for each power supply, as

well as the power enclosure itself.
Also included in the power fault realm is control of the electronic fuses between the power backplane and the
server or switch bays. The Onboard Administrator will alert on fuse trips to enable you to reset fuses

manually.
When installing additional power supplies into the enclosure, different power supply part numbers are not

supported in the same enclosure. Onboard Administrator warns which power supplies must be replaced with
a caution icon.

NOTE:

HP 1200W Common Slot Silver Hot Plug Power Supplies, spare part numbers

441830-001 and 498152-001 can be combined in an enclosure and are treated as equivalent

for the purposes of power supply mixing.

For proper installation of the power supplies into the enclosure, see the HP BladeSystem c7000 Enclosure

Setup and Installation Guide.