Thermal subsystem – HP Onboard Administrator User Manual

Page 261

Advertising
background image

Configuring the HP BladeSystem c7000 enclosure and enclosure devices 261

Column

Description

Fan Speed

The fan speed is displayed as a percentage of maximum RPM.

Thermal subsystem

Onboard Administrator monitors up to 10 fans in the enclosure and adjusts fan speeds as necessary, based

on thermal and power measurements. The speed of individual fans can be adjusted to reduce noise and

power consumption, and to compensate for airflow differences within the enclosure. The performance of
each fan is monitored, and Onboard Administrator reports any failures or warnings to the system log and HP

SIM (when SNMP is enabled).
Monitoring fan zones is only available on the c7000 Enclosure. All other thermal subsystem features and

functions are the same for c3000 and c7000 Enclosures, except where noted.
The following screen shows the Fan Summary page for a c7000 Enclosure.

Fan Summary
This screen provides status on the thermal subsystem and each individual fan.
Fan subsystem status

Row

Description

Thermal Subsystem
Status

Indicates the overall status of the fan subsystem. Possible values are Unknown, OK,
Degraded, or Critical Error.

Redundancy

Indicates the redundancy status of the fans. Possible values are Redundant or Not

Redundant

Fan Location Rule

The fan location rule indicates the proper location of the fans and the device bays that
are supported.