Half-height server blade
The following table lists the port mapping for half-height server blades installed in c7000 device bay N
(1-16).
Connection
Port number
Connects to
interconnect bay/port
Embedded NIC
NIC 1
NIC 2
1/Port N
2/Port N
Mezzanine 1
Port 1
Port 2
3/Port N
4/Port N
Mezzanine 2
Port 1
Port 2
Port 3
Port 4
5/Port N
6/Port N
7/Port N+8
8/Port N+8
Full-height server blade
The following table lists the port mapping for full-height server blades installed in device bay N (1-8).
Connection
Port number
Connects to interconnect bay/port
Embedded NIC
NIC 1
NIC 2
NIC 3
NIC 4
1/Port N+8
2/Port N+8
1/Port N
2/Port N
Mezzanine 1
Port 1
Port 2
Port 3
Port 4
3/Port N
4/Port N
3/Port N+8
4/Port N+8
Mezzanine 2
Port 1
Port 2
Port 3
Port 4
5/Port N
6/Port N
7/Port N
8/Port N
Mezzanine 3
Port 1
Port 2
Port 3
Port 4
7/Port N+8
8/Port N+8
5/Port N+8
6/Port N+8
Double dense server blade
The following table lists the available configurations for double dense devices installed in device bay N
(1-16).
Connection
Port Number
Connects to interconnect bay/port
Server A Embedded NIC
NIC 1 (Port:1)
NIC 2 (Port:2)
1/Port N
3/Port N
Server A Mezzanine*
Port 1
Port 2
5/Port N
6/Port N