Insight display screen shot errors, Onboard administrator factory default settings, Onboard administrator snmp traps – HP Onboard Administrator User Manual

Page 318

Advertising
background image

Troubleshooting 318

543 This version of Onboard Administrator firmware does not support boot options for servers configured in

UEFI boot mode.
561 Transmission from the HP Insight Remote Support receiver was unsuccessful.
562 Transmission from the HP Insight Remote Support receiver was unsuccessful. Please check connectivity

between OA and the Insight Remote Support receiver.
563 The key strength for the provided key is invalid for this configuration.
564 This command is not supported by the interconnect.
565 The string entered is a link-local address and cannot be used for assignment.

Insight Display screen shot errors

1 Missing credentials.
2 The getLCDImage CGI process has caught the SIGSEGV signal.
3 Could not acquire access to the image in a reasonable amount of time.
4 Cannot open semaphores.
5 Produce SEMV does not work.
6 Consume SEMV does not work.
7 Cannot lock the image file.
8 Cannot open the image file.
9 Cannot seek in the image file.
10 Unable to resume session.
11 Insufficient privileges.

Onboard Administrator factory default settings

When resetting the HP BladeSystem Onboard Administrator to factory defaults, the administrator password

is not reset to factory default. It remains set to the password that was last specified. In the event that the

administrator password must be reset to factory defaults (as included on the tag that shipped with the
Onboard Administrator), proceed to the Recovering the administrator password (on page

19

) section in this

guide.
Resetting the Onboard Administrator to factory defaults will also reset any certificates on the Onboard

Administrator.

Onboard Administrator SNMP traps

The BladeSystem Onboard Administrator supports the following SNMP traps.

Trap ID

Trap name

Description

22001

cpqRackNameChanged

Rack Name has changed

22002

cpqRackEnclosureNameChanged

Enclosure Name has changed

22003

cpqRackEnclosureRemoved

Linked Enclosure removal detected

22004

cpqRackEnclosureInserted

Linked Enclosure insertion detected