Insight display screen shot errors, Onboard administrator factory default settings, Onboard administrator snmp traps – HP Onboard Administrator User Manual
Page 318

Troubleshooting 318
543 This version of Onboard Administrator firmware does not support boot options for servers configured in
UEFI boot mode.
561 Transmission from the HP Insight Remote Support receiver was unsuccessful.
562 Transmission from the HP Insight Remote Support receiver was unsuccessful. Please check connectivity
between OA and the Insight Remote Support receiver.
563 The key strength for the provided key is invalid for this configuration.
564 This command is not supported by the interconnect.
565 The string entered is a link-local address and cannot be used for assignment.
Insight Display screen shot errors
1 Missing credentials.
2 The getLCDImage CGI process has caught the SIGSEGV signal.
3 Could not acquire access to the image in a reasonable amount of time.
4 Cannot open semaphores.
5 Produce SEMV does not work.
6 Consume SEMV does not work.
7 Cannot lock the image file.
8 Cannot open the image file.
9 Cannot seek in the image file.
10 Unable to resume session.
11 Insufficient privileges.
Onboard Administrator factory default settings
When resetting the HP BladeSystem Onboard Administrator to factory defaults, the administrator password
is not reset to factory default. It remains set to the password that was last specified. In the event that the
administrator password must be reset to factory defaults (as included on the tag that shipped with the
Onboard Administrator), proceed to the Recovering the administrator password (on page
) section in this
guide.
Resetting the Onboard Administrator to factory defaults will also reset any certificates on the Onboard
Administrator.
Onboard Administrator SNMP traps
The BladeSystem Onboard Administrator supports the following SNMP traps.
Trap ID
Trap name
Description
22001
cpqRackNameChanged
Rack Name has changed
22002
cpqRackEnclosureNameChanged
Enclosure Name has changed
22003
cpqRackEnclosureRemoved
Linked Enclosure removal detected
22004
cpqRackEnclosureInserted
Linked Enclosure insertion detected