Changing the cutoff frequencies (low and, High frequency) to adjust the passband width, Characteristics -6 – Kenwood TS-990S User Manual

Page 144

Advertising
background image

6 REJECTING INTERFERENCE

6-6

Index

Contents

CHANGING THE CUTOFF FREQUENCIES (LOW

AND HIGH FREQUENCY) TO ADJUST THE

PASSBAND WIDTH CHARACTERISTICS

In the SSB, AM, or FM mode, you can modify the

passband width of the filter by changing the cutoff

frequencies (low and high frequency).

You can change the passband width so that interference will

be outside the bandwidth of the filter.

Low Cut Frequency Range

Interfering

Signal

Target Signal

Interfering

Signal

High Cut Frequency Range

0 Hz 1 KHz

5 KHz

[ESC]

[FIL/SEL] (M)

Mode keys

[HI/SHIFT]

[FIL/SEL] (S)

[LO/WIDTH]

1 Press one of mode keys to select LSB, USB, FM, or

AM mode.

2 Press and hold [FIL/SEL] (M) or [FIL/SEL] (S) to open

the RX Filter screen.

The selected band and the mode name while receiving

appear, and the selected RX filter (A, B, or C) is activated.

3 Rotate either HI/SHIFT or LO/WIDTH control.

• Rotating the HI/SHIFT control clockwise increases the

high cutoff frequency and rotating it counterclockwise

decreases the high cutoff frequency.

• Rotating the LO/WIDTH control clockwise increases the

low cutoff frequency and rotating it counterclockwise

decreases the high cutoff frequency.

• The changes of the shift and filter type appear on the RX

Filter screen.

4 Press [ESC] to exit.

Pressing [FIL/SEL] (M) or [FIL/SEL] (S) closes the RX Filter

screen.

Note:

◆ You can view the progress of adjustments while the sub-scope

appears on the sub-screen.

Mode

Cutoff frequency (low) (Hz)

Cutoff frequency (high) (Hz)

Range

Default

Range

Default

LSB/USB/

FM

0, 50, 100, 200,

300, 400, 500,

600, 700, 800,

900, 1000

200

1000, 1200, 1400,

1600, 1800, 2000,

2200, 2400, 2600,

2800, 3000, 3400,

4000, 5000

2800

AM

0, 100, 200, 300

100

2500, 3000, 4000,

5000

5000

Advertising