Transmit power limiter, Meter, Changing the meter type – Kenwood TS-990S User Manual

Page 72: Transmit power limiter -18, Meter -18, Changing the meter type -18

Advertising
background image

4 BASIC OPERATIONS

4-18

Index

Contents

METER

The meter for the main band displays the signal as an

S-meter while receiving and as the selected meter while

transmitting. The meter for the sub band always displays

the readout of the S-meter. The meter type for the main

band displayed on the main screen can be changed.

[MENU]

F[METER]

[F1] [F7]

CHANGING THE METER TYPE

You can select the meter display pattern, showing the

main band status, from a digital pattern or two analog

patterns.
1 Select Group No. 0, "Basic Configurations", from the

Menu screen.

2 Access Menu 10, "Meter Display Pattern".
3 Press [SELECT] (F4) to allow editing of the parameter

box.

4 Press [-] (F4) or [+] (F5) to select "Type 1" (Digital),

"Type 2" (Analog 1), or "Type 3" (Analog 2).

The default is "Type 2" (Analog 1).

5 Press [

] (F1).

6 Press [MENU] to exit.

Type 1 (Digital Meter)

TRANSMIT POWER LIMITER

You can place a limit on the transmit power of your

transceiver. This function prevents the transmit power

from exceeding the configured transmit power limit even

with further rotation of the PWR control. You can also set a

different transmit power limit for the DATA mode.
1 Press [MAX-Po] (F) to open the TX Output Limit

screen.

2 Press [

] (F4) or [

] (F5) to highlight a line

for a frequency band.

3 Press [

] (F2) or [

] (F3) to select the

transmit power to be controlled.

As shown below, you can select the item to limit the transmit

power.

Max Power Limit

Transmit power limit for normal transmission.

Max Power Limit (DATA)
Enables the configuration for the transmit power limit while in DATA

Mode.
TX Tune Power

Enables the configuration for the transmit power limit for the

TX Tuning.

{page 9-14}

4 Press [-] (F6) or [+] (F7), or rotate the MULTI/CH

control to select the limit value for the transmit power.

Press and hold [(RESET)] (F1) to revert the limit value for the

selected item to the default.

5 Press [MAX-Po] (F) or [ESC] to exit.

Note:

◆ If "On" (with the 5 W transmit power reduction enabled) is

configured in Advanced Menu 08, "TX Power Down with

Transverter Enabled", [MAX-Po] (F) on the right side of the main

screen and the wattage value on the key guide will disappear when

the transverter or drive-out is activated.

◆ If ANT1 is selected for the transceiver for use with an external

antenna tuner, the maximum transmit power is limited to 100 W.

Even if greater than 100 W is configured for the transmit limiter, the

display on the key guide of [MAX-Po] (F) remains as 100 W as well

as the display on the main screen (100 W).