Configuring the ref i/o connector, Configuring the passband width, Configuring the ref i/o connector -22 – Kenwood TS-990S User Manual

Page 254: Configuring for the rooofing filter added by you, Main band only) -22, Configuring the passband width -22, Signal, Anced menu 6

Advertising
background image

16 USEFUL FUNCTIONS

16-22

Index

Contents

CONFIGURING THE REF I/O CONNECTOR

The behavior of the REF I/O (10 MHz) connector on

the rear panel can be selected from "Off", "Input", and

"Output".

• Impedance : 50Ω

The frequency accuracy can be increased by entering the

sufficiently accurate reference signal to the transceiver

and by using the signal as the reference frequency.

• Input Level : 0dBm ± 10dB

Also, sourcing the reference frequency of the transceiver

via the REF I/O (10 MHz) connector enables to be used

as the reference frequency of other transceiver.

• Output Level : 0dBm

[F1] [F7]

F[ADV.]

[MENU]

7 Press [ADV.] (F) from the Menu screen to open the

Advanced Menu screen.

8 Access Menu 4, "REF I/O Connector Configuration".
9 Press [SELECT] (F4) to allow editing of the parameter

box.

10 Press [-] (F4) or [+] (F5) to select the behavior of the

REF I/O (10 MHz) connector from "Off", "Output", or

"Input".

The default is "Off".

11 Press [

] (F1).

12 Press [MENU] to exit.

CONFIGURING FOR THE ROOOFING FILTER

ADDED BY YOU (MAIN BAND ONLY)

If you add a roofing filter, you can configure the passband

width and attenuation of the roofing filter according to the

specifications of the roofing filter.

[F1] [F7]

[MENU]

F[ADV]

CONFIGURING THE PASSBAND WIDTH

You can configure the passband width according to the

specifications of the roofing filter that you have added.
1 Press [ADV.] (F) from the Menu screen to open the

Advanced Menu screen.

2 Access Advanced Menu 06, "Bandwidth (Additional

Roofing Filter)".

3 Press [SELECT] (F4) to allow editing of the parameter

box.

4 Press [-] (F4) or [+] (F5), or rotate the MULTI/CH

control to select the passband width.

You can select "Off" or "300 [Hz]" to "3500 [Hz]" for the

passband width. The default is "Off". If you do not add a

roofing filter, do not change the parameter from the default

("Off").

5 Press [

] (F1).

6 Press [MENU] to exit.

Note:

◆ As of February 2013, no optional roofing filters will be available

from KENWOOD.

◆ If you select "Auto" for the roofing filter on the RX Filter screen, a

roofing filter with a passband width wider than that of the DSP filter

is selected. If there are two or more roofing filters, including the

one that you add satisfying the conditions, the roofing filter with the

narrowest passband width is selected.

◆ If anything other than "Off" is configured for the passband width,

you can select "Add." for the line for "Roof" in the RX Filter screen.

Advertising