Manual notch filter (ssb, cw, fsk, and psk), Manual notch filter (ssb, cw, fsk, and psk) -10 – Kenwood TS-990S User Manual

Page 148

Advertising
background image

6 REJECTING INTERFERENCE

6-10

Index

Contents

■ Adjusting the Noise Blanker levels for the sub

band.

1 Press and hold [NB1/SEL] or [NB2/SEL].

The Noise Blanker 1 (Sub) screen or Noise Blanker 2

(Sub) screen appears.

Note:

◆ If the transceiver receives the CW signal while Noise Blanker 2 is

active, the received audio may be distorted.

2 Press [-] (F4) or [+] (F5), or rotate the MULTI/CH

control to adjust the level.

• You can adjust the level of Noise Blanker 1 or Noise

Blanker 2.

• The available range is "1" to "10". The default is "6".

Noise is suppressed more effectively if a larger value is

configured.

3 Press [ESC] to exit.

Pressing and holding [NB1/SEL] or [NB2/SEL] closes the

Noise Blanker 1 (Sub) screen or Noise Blanker 2 (Sub)

screen.

MANUAL NOTCH FILTER (SSB, CW,

FSK, and PSK)

The manual notch filter is an IF-stage notch filter that

suppresses beat interference.

You can use the manual notch filter to eliminate beat noise

and catch weak signals or operate the transceiver while

checking the status of noise.

[NOTCH] (S)

[NCH/SEL] (M) [NCH/SEL] (S)

[NOTCH] (M)

■ Activating or deactivating the Manual Notch filter
1
Press [NCH/SEL] (M) or [NCH/SEL] (S) to enable the

manual notch filter for the selected band.

• The "NCH/SEL" (M) LED or "NCH/SEL" (S) LED lights

green. In the main screen, "NOTCH" appears on the upper

left side of the frequency display for the selected band.

• The letter "Y" appears to indicate the notch frequency if the

filter type is displayed in the sub screen.

• Press the key again to deactivate the manual notch filter for

the selected band.

Notch Frequency

2 Rotate the NOTCH (M) or NOTCH (S) control.

Adjust the notch frequency to the point where the beat or

interference is suppressed. The letter "Y" indicating the notch

frequency moves left and right if the filter type appears on the

sub-screen.

Note:

◆ The manual notch filter is deactivated if the auto notch filter or band

elimination filter is active.

◆ The notch point against an interfering beat cannot be changed

even if a pitch and shift is changed after the notch point is

determined in CW mode.

Advertising