11 scan, Program scan, Starting the program scan (vfo scan) – Kenwood TS-990S User Manual

Page 193: Program scan -1, Starting the program scan (vfo scan) -1, Configuring the program scan (vfo scan) frequency, Range -1

Advertising
background image

11-1

11 SCAN

Index

Contents

Scan is a function that searches for the availability of a

signal by shifting the frequency. This transceiver has the

following scans to search for the signal.

Scan Type

Purpose

Normal Scan

Program

Scan

Scans on the frequency range

stored in the Programmable Memory

Channels P0 to P9.

VFO Scan

Scans on all receive frequency

range. If all Programmable Memory

Channels are deselected (do not

allow scanning), the transceiver does

VFO scan, instead of Program Scan.

Scans using

Memory

Channels

All Channel

Scan

Scans on all Memory Channels, 00 to

99, P0 to P9, and E0 to E9.

Group

Scan

Scans on the grouped Memory

Channels.

QUICK

MEMORY

SCAN

Scans on the Quick Memory

Channels.

PROGRAM SCAN

Program Scan scans in the frequency range between the

Start frequency and End frequencies configured for the

Program Memory Channels P0 to P9.

You can configure the frequency range for Program Scan

for Program Memory Channels P0 to P9. A maximum of

10 frequency ranges may be used by the specific station.

If the transceiver can be on standby state on the adjacent

frequencies, it is easy to tune to the specific station after

the specific station starts a QSO using the frequency

range.

[MULTI/CH]

[ESC]

[M/V]

[F1] [F7]

Note:

◆ With Program Scan, the transceiver scans on the frequency

range between the start frequency and the end frequency of the

Programmable Memory Channel, and moves to the next channel

after the transceiver finishes the scanning on the specified

frequency range.

◆ Press [

] while pressing down [PF A] when the transceiver

power (

) turns OFF starts up the transceiver power (

) with

Auto Voice Guidance enabled.

◆ The transceiver scans from the lower frequency to the higher

frequency. If the end frequency is changed to be lower than the

start frequency with a rotation of the Tuning or MULTI/CH control,

the transceiver scans from the higher frequency to the lower

frequency.

◆ The step frequency for scanning is the same frequency step size

as that of the Tuning control for use in SSB, CW, FSK, and PSK

modes, 100 Hz for use in AM mode, and the same frequency step

size as that of the MULTI/CH control for use in FM mode.

◆ The scan stops when the transceiver receives a signal during the

Program Scan (VFO Scan) in FM mode or during the Memory Scan

(All Channel Scan, Group Scan) or the Quick Memory Scan. Refer

to "RESUMING THE SCANNING" for the conditions to resume

scanning.

{page 11-6}

◆ While the transceiver is on stand by, in FM mode, to receive a

CTCSS tone, the scan stops only if the received CTCSS tone

matches the CTCSS tone configured for the transceiver.

◆ In FM mode, if the transceiver exceeds the critical squelch level by

rotating the SQL control clockwise, the scan does not stop even if

a signal is present. The squelch level must be set near the critical

squelch level.

◆ If the transceiver receives only using the main band, the transceiver

does not scan using the sub band.

◆ While Frequency Tracking is active, the scan does not start.

STARTING THE PROGRAM SCAN (VFO SCAN)

1 Press [M/V] to enter VFO mode.
2 Press [SCAN] (F5) to start the Program Scan (VFO

Scan).

Pressing [SCAN] (F5) again or pressing [ESC] stops

Program Scan (VFO Scan).

CONFIGURING THE PROGRAM SCAN (VFO SCAN)

FREQUENCY RANGE

You can configure whether the transceiver scans the

frequency range specified with the Program Memory

Channel (Program Scan), or receive all frequency range

(VFO Scan).

Refer to "CONFIGURING NAMES FOR MEMORY

CHANNELS" for the configuration of the Program Memory

Channel.

{page 10-7}

1 Press [M/V] to enter VFO mode.
2 Press and hold [SCAN] (F5) to open the Program

Scan screen.

3 Press [

] (F2) or [

] (F3) to select a channel

for Program Memory Channel.

4 Press [

] (F4) to determine whether or not the

transceiver scans the Program Memory Channels.

• Each key press toggles a tick mark between places (allows

scanning) or removes (does not allow scanning).

• To use VFO Scan, all tick marks on all Program Memory

Channels must be removed (deselected).

• Pressing [SEL.ALL] (F6) selects and places a tick mark on

all Program Memory Channels.

• Pressing [CLR.ALL] (F7) deselects and removes the tick

marks from all Program Memory Channels.

5 Press [ESC] to exit.

Advertising