11 SCAN

11-2

Index

Contents

Note:

◆ Configuration examples for Program Scan and VFO Scan:

• Place tick marks to the Program Memory Channels, P1, P3

and P5, and then press [SCAN] (F5). The transceiver starts

the Program Scan to scan the frequency range stored on each

channel.

• Remove all tick marks from all Program Memory Channels, and

then press [SCAN] (F5). The transceiver starts the VFO Scan to

scan all receive frequency ranges.

• A tick mark is removed from a Program Memory Channel to which

no operating data has been configured, and you cannot place a

tick mark.

CHANGING THE SCAN SPEED

In any mode other than FM mode, you can change the

scan time to remain on each frequency for Program Scan

(VFO Scan).

[MULTI/CH]

[M/V]

[F1] [F7]

Tuning (M)

[MENU]

1 Press [-] (F3) or [+] (F4) during the Program Scan

(VFO Scan).

The scan speed appears below the frequency display.

The scan time to remain on each channel varies as below.

Display

Time Intervals

SCAN-SPD1

10 ms

SCAN-SPD2

30 ms

SCAN-SPD3

100 ms

SCAN-SPD4

150 ms

SCAN-SPD5

200 ms

SCAN-SPD6

250 ms

SCAN-SPD7

300 ms

SCAN-SPD8

350 ms

SCAN-SPD9

400 ms

Note:

◆ In FM mode, the scan time to retain each frequency during the

Program Scan and VFO Scan is fixed to 80 ms, and you cannot

change the scan time. However, if the transceiver receives a

CTCSS tone, the scan time is extended to 400 ms. In FM mode,

"SCANNING" appears in place of the scan speed.

SCAN HOLD

In any mode other than FM mode, changing the frequency

with a rotation of the Tuning or MULTI/CH control during

the Program Scan (VFO Scan) stops scanning for five

seconds.

The transceiver can temporarily receive without stopping

the scan.

Follow the procedure below to enable the Scan Hold.
1 Select Group No. 4, "Memory Channels & Scan", from

the Menu screen.

2 Access Menu 04, "Scan Hold".
3 Press [SELECT] (F4) to allow editing of the parameter

box.

4 Press [-] (F4) or [+] (F5) to select "On".

The default is "Off"

5 Press [

] (F1).

6 Press [MENU] to exit.

If Scan Hold is enabled in Menu 4-04, the transceiver can

receive a signal by stopping the Program Scan for five

seconds.
7 Press [SCAN] (F5) to start the Program Scan (VFO

Scan).

8 Rotate the Tuning or MULTI/CH control to increase or

decrease the frequency.

Program Scan (VFO Scan) stops for five seconds. Then, the

transceiver resumes the Program Scan (VFO Scan).

Advertising